Triple Whole House Town Water Filtration System
At a Glance
Application
Whole house / point-of-entry water filtration
Water Source
Town water
Filtration
Three-stage sediment, carbon and PFAS filtration
Installation
Point-of-entry installation by a licensed plumber
| System | Triple Whole House Town Water Filtration System |
|---|---|
| Max. Flow | 15.1 L/min (4 gpm) |
| Operating Pressure | 207–620 kPa (30–90 psi) |
| Operating Temperature | 4.4–37.8°C |
| Certification | NSF/ANSI 42 and NSF/ANSI 53 certifications apply to specified individual filtration components and claims. |
| Technical Notes |
| Installation | External point-of-entry installation to the home's cold water supply. |
|---|---|
| Installer | Licensed plumber required. Installation must conform to AS/NZS 3500.1 and all applicable local plumbing codes. |
| Connections | 1" connections. Connect to cold water only. Cold water only. Town water configuration uses a 20 mm inlet. Install before any internal cold water branch points. Dual check valve and 500 kPa pressure limiting valve are supplied. Upstream and downstream isolation valves are required, and installation of a bypass is strongly recommended. |
| Service Clearance | Allow sufficient access for cartridge replacement and servicing. Minimum 50 mm gap shown in the PWS installation configuration. |
Technical Drawing
| Filtration Configuration | Stage 1 – DGD gradient-density sediment filtration Stage 2 – RFC20-BB radial-flow granular activated carbon filtration Stage 3 – FloPlus Protect 20BB PFAS filtration |
|---|---|
| Filtration Performance | |
| PFAS | The FloPlus Protect 20BB final filtration stage is certified for reduction of PFOA, PFOS, PFHxS, PFNA and PFHpA. Pentair states reduction of these five PFAS compounds up to 99.82%. Refer to the applicable Pentair Performance Data Sheet for individual contaminant reduction claims and test conditions. |
Performance Testing:
Individual filtration stages have manufacturer performance data and applicable third-party certification. System-level recommended operating parameters reflect the most restrictive applicable component specifications.
Performance may vary depending on incoming water quality, flow rate, usage and cartridge condition. Refer to applicable cartridge performance data for specific contaminant reduction claims and test conditions.
| System | |
|---|---|
| Cartridges | |
| Fittings & Hardware | |
| Safety & Protection |
Installation of this system must be carried out by a licensed plumber in accordance with the Plumbing Code of Australia (PCA), AS/NZS 3500 (all relevant parts), and any applicable state or local regulations.